Product description
LCLE PRO-4040 – Dow FilmTec™ (USA) reverse osmosis membrane optimised for systems with lower operating pressure requirements. Provides high salt rejection and good output with lower energy consumption.
Key parameters
- Permeate flow: 9,8 m³/d. (≈ 9 800 l/d.)
- Min. salt rejection: 99,0 %
- Stabilised salt rejection: 99.5% (technical data also states 99.2%)
- Nominal active area: 8,7 m²
- Operating pressure (test): 10,3 bar
Test conditions: 2,000 mg/l NaCl, 25 °C, 15% recovery.
Note: the flow of individual elements may vary, but not by more than 15 % the values stated below.
Note: the flow of individual elements may vary, but not by more than 15 % the values stated below.
Operating conditions
- Max. water temperature: 45 °C
- Max. operating pressure: 41 bar)
- Max. pressure drop (ΔP): 1,0 bar
- pH (operation): 2–11
- pH (chemical cleaning): 1–13
- Max. SDI: < 5
- Free chlorine: < 0.1 mg/l
- Max. pressure drop over the whole housing length: 2,1 bar
Start-up and maintenance
- Before start-up: prepare the membrane, fill the elements, adjust the equipment and check the system.
- Avoid sudden pressure / flow surges (during start-up, shutdown and cleaning).
- Recommended start-up:
- Increase pressure gradually over 30–60 s
- Bring flows up to operating level over 15–20 s
- For the first 1 val. discharge the permeate to drain
- After initial soaking, the elements must always be kept wet.
- For long shutdowns it is recommended to preserve the elements (protect from biofouling) with a preservation solution.
Outstanding features
- Dow FilmTec™ – the global standard for RO water treatment
- Up to 9,800 l/d of consistent-quality water for business
- Energy efficiency thanks to lower operating pressure
- Large active area – higher output
- High-precision manufacturing – maximum active area and consistent quality