Filmtec™ membrane 8″ XLE440

966.79 €

PARAMETERS
  • Permeate volume: 53 m³/day
  • Working pressure: 8.6 bar
  • Nominal active surface: 41 m²
  • Stabilised salt rejection: 99.0%
  • Max. working pressure: 41 bar
  • Max. operating water temperature: 45 °C

KEY FEATURES
  • The Dow Filmtec™ membrane (USA) – the global standard in water treatment.
  • Clean water for business – 53,000 litres of consistent-quality water per day.
  • High energy efficiency thanks to low operating pressure.
  • The large active element surface ensures higher capacity.
  • Automated, high-precision manufacturing produces elements with maximum active surface.

SPECIFICATIONS


Technical data
  • Nominal active surface – 41 m²
  • Working pressure – 8.6 bar
  • Permeate volume – 53 m³/day
  • Stabilised salt (NaCl) rejection – 99.0%
Permeate flow and salt (NaCl) rejection are given under these test conditions: 2,000 mg/L NaCl, 25 °C, pH 8, stated pressure and 15% permeate recovery.
The permeate flow of each individual element may vary but will not exceed ±15% of the stated values.

Operating conditions
  • Maximum operating water temperature – 45 °C
  • Maximum operating pressure – 41 bar
  • Maximum pressure drop – 1.0 bar
  • pH range, operating mode – 2…11
  • pH range, chemical cleaning mode – 1…12
  • Maximum feed water silt density index SDI < 5
  • Free chlorine tolerance – <0.1 mg/L

Maintenance
Before starting up the reverse osmosis system, initial membrane preparation, element loading, equipment adjustment and other system checks must be carried out.

Avoid large pressure or flow surges in spiral-wound elements during start-up, shutdown, cleaning, etc., to avoid the risk of membrane damage. During start-up, it is recommended to switch the system gradually from standby to operating mode as follows:
  • increase feed water pressure gradually over 30–60 seconds;
  • establish the operating flow gradually over 15–20 seconds;
  • discard (drain) the permeate produced during the first hour of operation.

Important information

  • After initial wetting, always keep the elements moist.
  • To prevent biofouling during long downtimes, it is recommended to immerse the membrane elements in preservation solutions.
  • The maximum pressure drop across the entire housing length is 2.1 bar.