ELP 8040-400 membranes are spiral-wound membrane elements for reverse osmosis systems. ELP 8040-400 membranes are designed for treating brackish water in low-pressure systems. The large active surface area and high rejection rate allow these membranes to be used under variable pressure and flow conditions without compromising filtration quality.
Parameters
- Permeate flow rate: 42 m³ per day
- Recovery: 15%
- Maximum operating pressure: 41 bar
- Maximum element pressure drop: 1.0 bar
- Operating pH range: 2…11
- Maximum chlorine concentration: 0.1 mg/L