Key features
- Water flow up to 42 m³/d, 29 l/min.
- The membrane is shipped dry
- Easy to install
Dimensions and weight

Dimensions – H×W×D: 1016 (A) x 201 (C) x 29 (B) mm
Weight – 18 kg
Specifications
Membrane type – spiral-wound polyamide thin-film composite element
- Working pressure – 10.3 bar
- Filtered water flow — 42.0* m³/d, 29 l/min
- Salt rejection — 99.0%
* Filtered water flow and salt (NaCl) rejection are based on these test conditions: 2,000 mg/L NaCl, 25 °C, 15% recovery. Under other conditions the data may differ, but by no more than 15% from the stated values.
Operating parameters
- Maximum feed water temperature – 45 °C
- Maximum pressure — 41 bar
- Maximum pressure drop – 1.0 bar
- pH range for continuous operation – 3…11
- pH range, short-term operation — 1.5…12
- Maximum silt density index (SDI) – 5
- Free chlorine tolerance < 0.1 mg/L
Maintenance
Before starting up the system, membrane pretreatment, loading of membrane elements, instrument calibration and other system checks must be carried out. See the product manual for more information.
Recommended steps when starting up the system:
- Inlet water pressure must be increased gradually over 30–60 seconds.
- The operating flow rate should be achieved gradually over a period of 15-20 seconds.
- Water filtered during the first hour of operation is not suitable for use.
Important information
- Once operation has started, all membrane elements must be kept wet.
- To prevent biological fouling during longer breaks in operation, it is recommended to immerse the membrane elements in preservation solutions.
- Maximum operating pressure drop – 2.1 bar.