Key features
- Water flow up to 34 m³/d, 23.6 l/min.
- The membrane is shipped dry
- Easy to install
Dimensions and weight

Dimensions, H×W×D: 1016 (A) x 201 (B) x 29 (C) mm
Weight 18 kg
Specifications
Membrane type – spiral-wound polyamide thin-film composite element
- Operating pressure — 6.9 bar
- Filtered water flow — 34.0* m³/d, 23.6 l/min
- Salt rejection — 99.0%
* Filtered water flow and salt (NaCl) rejection are based on these test conditions: 2,000 mg/L NaCl, 25 °C, 15% recovery. Under other conditions the data may differ, but by no more than 15% from the stated values.
Operating parameters
- Maximum feed water temperature – 45 °C
- Maximum pressure — 41 bar
- Maximum pressure drop – 1.0 bar
- pH range for continuous operation — 3…10
- pH range, short-term operation — 2…12
- Maximum silt density index (SDI) – 5
- Free chlorine tolerance < 0.1 mg/L
Recommended steps when starting up the system:
- Inlet water pressure must be increased gradually over 30–60 seconds.
- The operating flow rate should be achieved gradually over a period of 15-20 seconds.
- Water filtered during the first hour of operation is not suitable for use.
Important information
- Once operation has started, all membrane elements must be kept wet.
- To prevent biological fouling during longer breaks in operation, it is recommended to immerse the membrane elements in preservation solutions.
- Maximum operating pressure drop – 2.1 bar.